ADVANTAGES OF LASER MONITOR OVER LED MONITORS

 

  • Only opacity monitor which does not have to be removed from stack while flue gas is   present to perform an all component "Clear Stack Zero" set.

 

  • Utilizes a Helium-Neon Green Laser thus less prone to ambient light interference than conventional LED sources since laser operates with a clearly defined known wavelength making the theoretical calculations and their results more predictable. Conventional LED sources operate over a broad range of wavelengths and produce spectrum changes with age.  Laser light is also not affected by moisture content of the particle due to an effect called “extinction”.  Forward or backward light scatter is dramatically reduced due to narrow beam diameter and the single pass principle, Laser is on average 5mm in diameter which will allow opacity beam to always stay on detector target.  Conventional opacities use an overfill method therefore any drift in            the beam may cause inaccuracies.

 

  • Cemtrex laser Monitor will compensate for zero and dirty window drift 40 times per second instead of conventional method of once per day.  This allows for accurate and consistent readings continuously.

 

  • Filter Audit can be accomplished with opacity unit on stack without having to utilize expensive jigs or even move the opacity monitor. This is accomplished by passing the laser light through fiber optic light pipe which is routed on outside of stack and is not affected by stack opacity.

 

  • Actually performs zero and dirty window calibration utilizing actual detector and not a mirror.

 

  • Can utilize plant instrument air source for purging requirements.  Only need 5-8 CFM for most applications.  Bulky blower fans are therefore not required.

 

  • Very small and compact design therefore making the monitor much lighter. 

 

  • Up to 300’ path length can be accomplished.

 

  • Monitor is standard with both Opacity and Particulate measurements.  Unit can display both Opacity and Particulate measurements simultaneously.

 

  • Opacity monitor can be located on any diameter stack without having to re-program or re-calibrate system.  This can be done since laser light is not affected by path length as conventional LED monitors are.  This means that customer can conveniently move their opacity to different locations at any time if needed.

 

  • Unit does not require an off stack zero upon installation therefore a clear stack condition is not needed to begin valid opacity measurements.

 

  • Can be used on stacks with temperatures as high as 1200 F.

 

  •  Optional Opacity Monitor LaserSoft Data Acquisition & Reporting System available.  A low cost alternative to bulky chart paper recorders or other full DAS’s for data storing and reporting.

 

 

 

 

 